An automated gate is powered machinery, and it is regulated as such
UL 325 governs the operator and its entrapment protection. ASTM F2200 governs the gate itself. Most non-compliant gates we inspect were compliant the day they were installed.
- Standards
- UL 325 & F2200
- Inspection
- Documented
- Certified
- ACI technician
How it works on a commercial site
Compliance is not a certificate you get once. Photo eyes drift out of alignment. Safety edges get clipped by a delivery truck and stop conducting. Someone disables a nuisance-tripping sensor to stop the gate stalling, and the entrapment zone it covered is now unprotected.
We inspect against both standards, document what we find with the reason it matters, and quote the retrofit separately so you can see exactly what you are paying to fix. Where a gate cannot be brought into compliance economically, we say that plainly rather than papering over it.
- Written inspection against UL 325 and ASTM F2200
- Every entrapment zone identified and its protection verified
- Photo eye alignment, safety edge continuity, and reversing tested
- Retrofit quoted separately from the inspection
- Carried out by ACI credentialed technicians
Typical working range
| UL 325 | Standard for the operator: classes, entrapment protection, and controls |
|---|---|
| ASTM F2200 | Standard for the gate: construction, gaps, guarding, and stops |
| Entrapment zones | Each identified and protected by two independent means |
| Primary protection | Inherent reversing built into the operator |
| Secondary protection | Photo eyes, safety edges, or equivalent per zone |
| Guarding | Exposed rollers, pinch points, and gaps guarded per F2200 |
| Stops | Positive stops at both ends of travel to prevent overtravel |
| Signage | Warning placards at each side of the gate |
If your gate was installed before the current revisions, or has been serviced by more than one contractor, it is worth an inspection. Non-compliance usually surfaces after an incident, which is the expensive time to find out.
Common questions
Is a UL 325 inspection a legal requirement?
The standards are referenced by code and by most insurers rather than being a standalone legal filing. In practice, after an incident, the question of whether the installation met UL 325 and ASTM F2200 is the first one asked.
What does an inspection cover?
Every entrapment zone on the gate, the class and configuration of the operator, inherent reversing, secondary protection devices and their alignment, guarding, positive stops, and warning signage. You get it in writing with photographs.
Our gate keeps stopping for no reason. Is that a safety fault?
Usually it is a photo eye out of alignment or a dirty lens, and it is a warning rather than a nuisance. The wrong response is to disable it. Call us and we will realign or replace it and keep the zone protected.
Need a gate that holds up to commercial duty?
We survey the opening, size the operator to the leaf, and hand you a written scope you can put out to bid.